
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
D-22
D
SERIES 552 – ABSOLUTE Digimatic Coolant Proof Ceramic Jaw Carbon Fibre
Caliper
•
A lightweight Digimatic caliper that uses CFRP
(Carbon Fibre Reinforced Plastics) in the beam
and jaws.
•
Rustless and nonmagnetic. Suitable for measuring
magnetic components.
1
6
1
7
0
0
0
0
0
0
• Dust-tight and water
protected IP66
•
Zirconia ceramic contact surfaces for high
resistance to wear..
•
Data output function allows integration into
statistical process control and measurement
systems.
J
K
A
E
F
D
10(.25)
B
H
10(.25)
C
G
DIMENSIONS
Unit: mm
SPECIFICATIONS
Inch/Metric
Code No. Range*
1
Resolution Accuracy*
2
Price
552-165-10 0 (20) - 450 mm / 0 (.5") - 18"
0.01 mm / .0005" ±0.04 mm / ±.002"
£1020.00
552-166-10 0 (20) - 600 mm / 0 (.5") - 24" £1060.00
*
1
( ): Minimum dimension in inside measurement.
*
2
Excluding quantizing error.
552-165-10
Technical Data
Scale type: ABSOLUTE electromagnetic induction
linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc.), 938882
Battery life: Approx. 5,000 hours in continuous use
Dust/water
protection level: IP66*
3
Standard accessory: Jaw clamps (2 pcs.), 05GZA033
*
3
Rustproofing treatment to be applied after use.
Functions
ABSOLUTE system measurement:
After power is turned ON, measurement can be started
without zero-setting if origin-setting was previously
performed. The ABS (absolute) origin position can be changed
by the ORIGIN button.
Zero-setting (INC measurement mode):
Displayed value can be set to zero at any arbitrary position of
the slider for comparative measurements.
Auto ON/OFF:
The reading on the LCD disappears after this instrument is idle
for a short time, but the origin point is retained. Moving the
slider causes the reading on the LCD to reappear.
Data output:
Models equipped with this function have an output port for
transferring measurement data to a Statistical Process Control
(SPC) system.
Data hold:
By using the data hold unit (option), the displayed value can
be held. This cannot be used with the data output function.
Presetting (ABS INC measurement mode):
Displayed value can be set to any arbitrary value.
Offsetting:
Automatically adds the thickness of the inside jaws to the
measured value so that the result can be read directly, without
calculation.
Inch/mm selection:
Switches the units of measurement (at any time).
Alerts:
In the unlikely event of a display overflow or calculation
error, an error message is displayed and measurement stops.
Measurement cannot continue until the error is corrected.
If the battery voltage drops below a certain point, the
battery indicator will turn on before measurement becomes
impossible, warning the user that the battery needs to
be replaced. If contamination on the surface of the scale
causes a calculation error, an error message is displayed and
measurement stops.
Optional Accessories
05CZA624: SPC data cable with pushbutton (1 m)
£58.50
05CZA625: SPC data cable with pushbutton (2 m)
£70.40
06ADV380A: USB Input Tool Direct USB-ITN-A (2 m)
£106.00
02AZD790A: SPC data cable for U-WAVE-T (160 mm)
£52.20
02AZE140A: SPC data cable for U-WAVE-T and footswitch
(160/500 mm)
£114.00
914053: Clamp box (1 pair)*
4
£117.00
914055: Centre-to-Centre jaws (1 pair)*
4
£157.00
914057: Point jaws*
4
£179.00
*
4
Refer to page D-20 for details.
Range A B C D E F G H J K
0 - 450 mm 640
100 18 41.2 25 91.8 35 65 8 R10
0 - 600 mm 790
Comentários a estes Manuais