Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
D-7
D
Calipers
SERIES 500 – ABSOLUTE Digimatic Caliper
The ZERO/ABS button allows the display to be
Zero-Set at any slider position along the scale
for comparison measurements. This button will
also allow return to the absolute (ABS) mode and
display of the true position from the origin
(usually jaws closed point).
Large and clear LCD readout.
Smooth slider movement makes for comfortable
operation.
20,000 hours battery life.
Can measure outside and inside dimensions,
depth, and steps.
Carbide-tipped jaw calipers give the longest life
when measuring rough finished parts, castings,
grinding wheels, etc.
Data output function allows integration into
statistical process control and measurement
systems.
Technical Data
Resolution: 0.01 mm (.0005")
Repeatability: 0.01 mm
Scale type: ABSOLUTE electrostatic linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc.), 938882
Battery life: Approx. 3.5 years under normal use
(20,000 hours for continuous use)
Functions
Absolute measurement:
After power is turned ON, measurement can be started
without zero-setting if origin-setting was previously
performed. The Absolute origin position can be changed by
the ORIGIN button.
Incremental measurement:
Display can be set to zero at any arbitrary position for
comparative measurements.
Scale contamination detection:
Contamination on the surface of the scale is detected and an
error message (ErrC) is displayed.
Low-voltage alert:
If the battery voltage becomes low, a “B” appears in the
display to alert the user before measurement is no longer
possible. A battery change advisory alert precedes this alert.
Data output:
Models equipped with this function have an output port for
transferring measurement data to a Statistical Process Control
(SPC) system.
Data hold:
By using the data hold unit (option), the displayed value can
be held. This cannot be used with the data output function.
Optional Accessories
(Only for models with data output function)
959149: SPC data cable with pushbutton (1 m)
£34.60
959150: SPC data cable with pushbutton (2 m)
£39.40
06ADV380C: USB Input Tool Direct USB-ITN-A (2 m)
£90.80
02AZD790C: SPC data cable for U-WAVE-T (160 mm)
£52.20
02AZE140C: SPC data cable for U-WAVE-T and footswitch
(160/500 mm)
£114.00
959143: Data hold unit
£17.00
B
A
C
E
D
Range A B C D E
0 - 150 mm 21 16.5 231 40
16
0 - 200 mm 24.5 20 288 50
0 - 300 mm 27.5 21.8 403 64 20
DIMENSIONS
Unit: mm
500-173
500-172-20
500-196-20
Vista de página 6