Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
D-5
D
Calipers
SERIES 500 – ABSOLUTE Digimatic Coolant Proof Caliper
•
Can be used in workshop conditions exposed to
coolant, water, dust or oil. Other specifications
and price are the same as the conventional
products. 100% inspection by air leak test is
performed to ensure quality and reliability.
•
Large LCD characters make the display easy to
read.
•
Easy to use – advanced design styling with only 1
button.
•
Incorporates Mitutoyo's ABSOLUTE measurement
system. No need to reset the origin.
•
SPC data output models can be integrated
into statistical process control and measurement
systems.
•
Can measure outside and inside dimensions,
depth, and steps.
•
The automatic power-on/off function shuts down
the LCD display after 20 minutes inactivity, but
the ABS scale unit origin is stored. Power is
restored when the slider is moved.
•
A convenient interface input tool is available
so that measurement data can be converted to
keyboard signals and input directly to commercial
spreadsheet software.
•
An inspection certificate is supplied as standard.
(However, this cannot be used as a calibration
certificate as it is undated.)
C
D
B
A
E
Range A B C D E
0 - 150 mm 21 16.5 233 40
16
0 - 200 mm 24.5 20 290 50
0 - 300 mm 27.5 21.8 404 64 20
Outside jaw thickness: 3.5 mm (500-714-10: 3.8 mm)
DIMENSIONS
Unit: mm
Technical Data
Resolution: 0.01 mm (.0005")
Repeatability: 0.01 mm
Quantizing error: Not including ±1 count
Dust/water protection
level: IP67*
1
Scale type: ABSOLUTE electromagnetic induction
linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc.), 938882
Battery life: Approx. 3 years under normal use (1
year: over 300 mm models)
*
1
Rustproofing treatment to be applied after use.
Functions
ABSOLUTE system measurement:
After power is turned ON, measurement can be started
without zero-setting if origin-setting was previously
performed. The ABS (absolute) origin position can be changed
by the ORIGIN button.
Zero-setting (INC measurement mode):
Displayed value can be set to zero at any arbitrary position of
the slider for comparative measurements.
Auto ON/OFF:
The reading on the LCD disappears after this instrument is idle
for a short time, but the origin point is retained. Moving the
slider causes the reading on the LCD to reappear.
Data output:
Models equipped with this function have an output port for
transferring measurement data to a Statistical Process Control
(SPC) system.
Inch/mm selection:
Switches the units of measurement (at any time).
Alerts:
In the unlikely event of a display overflow or calculation
error, an error message is displayed and measurement stops.
Measurement cannot continue until the error is corrected.
If the battery voltage drops below a certain point, the
battery indicator will turn on before measurement becomes
impossible, warning the user that the battery needs to
be replaced. If contamination on the surface of the scale
causes a calculation error, an error message is displayed and
measurement stops.
Optional Accessories
05CZA624: SPC data cable with pushbutton (1 m)
£58.50
05CZA625: SPC data cable with pushbutton (2 m)
£70.40
06ADV380A: USB Input Tool Direct USB-ITN-A (2 m)
£106.00
02AZD790A: SPC data cable for U-WAVE-T (160 mm)
£52.20
02AZE140A: SPC data cable for U-WAVE-T and footswitch
(160/500 mm)
£114.00
500-753-10
500-737-10
Comentários a estes Manuais